The Fuel Management System to Grow Your Business
With user-friendly navigation, streamlined inventory and compliance reporting, and powerful business analytics, the TLS-450PLUS Automatic Tank Gauge (ATG) is a fuel management tool that allows you to run fueling operations at peak efficiency. And, with frequent releases of operating software for the TLS-450PLUS tank gauge you can be assured that data is secure and software features are routinely updated and enhanced.
The Hub of Your Compliance Program
Maintaining compliance is vital to ensuring you’re not cutting into profits with costly fines or fees. The TLS-450PLUS ATG is designed to help you meet those requirements and maintain records for regulatory purposes. With the availability to connect to a multitude of devices, and features like Continuous Statistical Leak Detection (CSLD) or Digital Pressurized Line Leak Detection (DPLLD), the TLS-450PLUS fuel management system provides flexibility to best suit your business.
Learn More About Leak Detection MethodsSee the Benefits of Upgrading
Learn more about the difference between the TLS-350 ATG and the enhanced features of the TLS-450PLUS ATG.
Featured TLS-450PLUS ATG Software Enhancements
Business Inventory Reconciliation (BIR)
Monitors fuel activity through dispenser transactions and tank inventory movement that generates highly accurate inventory reconciliation data for in active underground storage tanks. BIR includes AccuChart™ In-Tank Calibration software to create a precise tank chart to reduce fuel variances to improve your bottom line.
Learn MoreContinuous Statistical Leak Detection (CSLD)
A certified leak-testing technology that continuously monitors fuel height and temperature to detect quiet periods in the underground storage tank and collect leak-detection data during idle times. CSLD uses sophisticated statistical analysis to evaluate all information and create a database for compliance reporting.
Learn MoreBalanced Tank Inventory Control
For store operators using manifolded tanks, the TLS-450PLUS ATG can be programmed using Dispense Mode to determine when to activate a specific tank based on the tanks fuel height, volume, or other setting specific to the pump configuration. Connects the TLS-450PLUS ATG with Red Jacket Control Boxes to give site managers total inventory control.
Learn MoreTLS-450PLUS ATG Features
Intuitive User Access
- Customize the home screen, by user, with Favorites to easily access commonly used screens
- Workflow Wizard for easy step by step configuration
- Large 8” color LCD touch screen navigation
- Contextual help functionality for every feature
- Customized alarm settings, automated reporting, and email notifications
Enhanced Business Analytics & Performance
- BIR improves business decisions by combining meter transaction sales with AccuChart 3.0 In-Tank Calibration to better understand site variances
- Timed Sudden Loss Detection monitors unexpected changes in inventory, exposing possible issues including theft during quiet periods
- Standard configuration allows for up to 64 inputs, expandable to 256 inputs
- Built-in data logging enables approved data transfer for wet stock management
Worry-Free Regulatory Compliance
- The largest throughput volume available for extended line leak detection, supporting ever-growing fuel site locations
- Third-party evaluated and certified leak detection systems by the National Work Group of Leak Detection Evaluators (NWGLDE), providing independent support of product effectiveness
- Streamlined reports allow quick and easy data access while eliminating manual recording errors
- Smart data back-up helps prevent data loss during system maintenance and power outages
KEEP YOUR DATA SECURE WITH THE TLS-450PLUS ATG
Frequent Software Updates
Stay ahead of potential threats and vulnerabilities with routinely updated operating software. Veeder-Root sets the industry standard for software deployment with Centralized Device Management, which manages console software updates across an entire network.
System Security
The TLS-450PLUS ATG provides the security needed for today’s connected world. Features such as strong encryption, configurable user access, and segmented network ports help ensure your network is safe at every level.
Custom User Access
Implementing a program for securing user access helps to reduce risks directly on the console. Using front panel security, username and password requirements, and predefined or custom user roles to assign permissions, the customer user access features of the TLS-450PLUS ATG supports secure access and data control.
Security is Built into the Process
Our iterative software development process and frequent software releases for the TLS-450PLUS ATG includes multiple active security scans based on identified industry vulnerabilities.
Specifications
Number of Tanks Monitored | 64 |
Number of Tanks Monitored with BIR | 32 |
Sensor Inputs | 99 of any one type |
Line Leak Testing | 16 lines |
High Voltage Outputs | 32 |
High Voltage Inputs | 32 |
Low Voltage Inputs | 16 |
Touch Screen Display | 8” Color LCD |
Printer | Thermal |
Connectivity |
|
Available Modules |
|
Storage Temperature Range | -40°F to +158°F (-40°C to +70°C) |
Operating Temperature Range | +32°F to +104°F (0°C to +40°C) |
Dimensions | 18.4" x 11" x 8.8" (46.74cm x 27.94cm x 22.35cm) |
Approvals |
|
TLS-450PLUS Operator Tips
Menu Overview
View more TLS-450PLUS Operator TipsEnvironmental Regulatory Reports
View more TLS-450PLUS Operator TipsBusiness Inventory Reporting
View more TLS-450PLUS Operator TipsProduct Form
Standard Console Software & Hardware Configurations
Product Number | Description |
---|---|
0333545-001 | TLS-450PLUS Application Software (Order one per console) |
0860091-302 | TLS-450PLUS Console with Display, Printer, 3 Ethernet and Dual USB/Expansion, Dual RS-232/RS-485, (UL/cUL) |
TLS-450PLUS USM & UIOM Modules
Product Number | Description |
---|---|
0332812-001 | Universal Sensor/Probe Interface Module (USM) for TLS-450PLUS |
0332813-001 | Universal Input/Output Interface Module (UIOM) for TLS-450PLUS |
0333564-001 | 10-Amp Relay Module for TLS-450PLUS |
0332812-006 | Universal Sensor/Probe Module with Atmospheric Module |
TLS-450PLUS Communication Modules
Product Number | Description |
---|---|
0332866-001 | Single RS-232 Interface Module |
0332868-001 | Dual RS-232 Interface Module |
0332870-001 | RS-232/RS-485 Dual Interface Module |
0332867-001 | Single RS-485 Interface Module |
0332869-001 | Dual RS-485 Interface Module |
Remote Connectivity Options for the TLS-450PLUS ATG
THE PLUS VIEW App
Android and Apple iOS based application for checking gauge data on a mobile connection.
Learn MoreWeb-Enabled Interface
Browser-based access to gauge data and management of configuration settings.
Learn MoreCentralized Device Management
CDM is a server-based software package to manage your entire network of sites.
Learn MoreDocuments
- TLS-450PLUS Sell Sheet (576047-250)
- TLS-450PLUS, TLS4 & TLS4B Specification Sheet (576047-204)
- TLS-450PLUS, TLS4, & TLS4B Automatic Tank Gauges (576047-276)
- Upgrade to the TLS-450PLUS Automatic Tank Gauge Sheet (576047-335)
- Benefits of Upgrading to the TLS-450PLUS (576047-304)
- TLS-450PLUS Automatic Tank Gauge Specifications (577014-455)
- Instructions for Retrieving Data for TLS-350 to TLS-450PLUS ATG Upgrade (576047-314)
- TLS-450PLUS Business Analytics (576047-277)
- TLS-450PLUS DEF Management (576047-258)
- Warnings and Alarms for Veeder-Root Automatic Tank Gauges (576047-315)
- TLS-450 to TLS-450PLUS Upgrade Instructions (577014-048)
- TLS-450PLUS Operators Quick Help Guide (577014-072)
- TLS-450PLUS Site Prep and Installation Manual (577014-073)
- TLS-350 to TLS-450PLUS Upgrade Instructions (577014-074)
- TLS-450PLUS Troubleshooting Guide (577014-075)
- TLS-450PLUS Board and Software Replacement Manual (577014-076)
- TLS-450PLUS Module Replacement Instructions (577014-077)
- TLS-450PLUS Hardware Replacement Manual (577014-078)
- TLS-450 and TLS-450PLUS Certification Site Prep Manual (577013-934)
- TLS-XB Console Site Prep and Installation Manual (577014-033)
- TLS-450PLUS/TLS4 Consoles Vapor Collection Monitoring: VaporIX Install, Setup And Troubleshooting (577014-363)
- TLS-450PLUS/TLS4 Operator's Manual (577014-110)
- TLS System Warnings and Alarms Troubleshooting Guide (577014-243)
- TLS-450PLUS Console Intelligent Pump Control Installation and Setup (577014-361)
- Pressure Management Control (PMC) TLS-450PLUS Consoles for VR Polisher Install, Setup, & Operation Manual (577014-460)
- In-Station Diagnostics (ISD) TLS-450PLUS Consoles for Healy Assist Install, Setup, & Operation Manual (577014-461)
- In-Station Diagnostics (ISD) Quick Reference Guide for TLS-450PLUS Consoles (577014-462)
- In-Station Diagnostics (ISD) Pressure Management Control (PMC) TLS-450PLUS Consoles Troubleshooting Guide (577014-463)
- In-Station Diagnostics (ISD) TLS-450PLUS Consoles for VR Polisher and Healy CAS Install, Setup, & Operation Manual (577014-484)